Search
Log in
Login:
Password:
Register
Forgot your password?

PA-622 Current Probe

Max. DC A Current: ± 100A DC. Max. AC A Peak: 200A p-p. Max. AC A RMS: 70Arms. Frequency Range: DC to 300kHz (-3dB). Max. Sensitivity: 10mA. Battery Type: 9V.

The PA-622 current probe enables a general purpose oscilloscope to display AC and DC current signals up to 100 amps Peak (70A RMS). The PA-622 current probe can also make AC and DC measurements with a multimeter by using the recommended accessory (BNC-to-banana) plug adapter.

Features

  • Max. ±100A DCA
  • Resolution: ≥10mA
  • Bandwidth: DC~300kHz
  • Rise Time: 1.2μs
  • Overrange Function
  • 10mV/A, 100mV/A Range
  • Adaptor/Battery Input
  • Separating Design,Convenient Durable

Specifications

Max. DC A Current± 100A DC
Max. AC A Peak200A p-p
Max. AC A RMS70A rms
Range Selection
Division
2 Range
10mV/A;100mV/A
Max. Sensitivity10mA
DC Accuracy Typical±3% ±50mA at 100mV/A
(50 mA to 10A peak range)
±4% ±50mA at 10mV/A
(500mA to 40A peak range)
±15% max at 100mV/A
(40A peak to 100A peak range)
Frequency RangeDC to 300kHz (-3dB)
Rise Time1.2μs (Typ.)
Battery Type and Life, typical9V NEDA 1604A, IEC 6LR61
13 hours minimum (1 each)
Max. Working Voltage
Max Floating Voltage
300V CAT III
600V CAT II
Cable Length 100 cm (3.3 feet)
Maximum Conductor Size 11 mm (0.43 inch)
Weight260 g (9.5 oz) (without battery)

Accessories

  • An Insulated BNC/BNC lead, length 100cm
  • AC Adapter
  • Connector BNC to Banana
  • Instruction Manual

Back to the section