|
Thermometers
ATE-2001 Thermometer
|
|
Microprocessor circuit assures maximum possible accuracy, provides special functions and features. Heavy duty & compact housing case. Build in temperature linearity & precision cold junction compensation circuit, high accuracy. Fitted with standard type K thermocouple input measuring socket. Multi functions, dual channel temp. input, differential temp. measurement, ℃/℉, 0.1/1 degree. Display: 13 mm(0.5"). Super large LCD display, easy readout. data hold. Dual function meter's display. Wide measuring range from -50 ℃ to 1230 ℃. Memory Recall Records Maximum and minimum readings with recall. Power Off: Auto shut off saves battery life. or manual off by push button. RESOLUTION: 0.1 ℃, 1 ℃,0.1 ℉,1 ℉. ACCURACY: ± ( 1 % + 1 ℃)
|
|
ATE-2002 Thermometer
|
|
Professional thermometer with high accuracy & 0.01 resolution. Super large LCD with unit display, easy readout. Accept multi type temp. probe input : platinum PT 100 ohm, thermocouple type K/J/T/E/R. Data hold function for stored the desired value on display. Memory function to record the maximum & minimum reading with recall. Data Output RS232 PC serial interface. Functions: ℃, ℉, 0.010.1 Data hold, relative measurement. Resolution: 0.01℃/0.1℃, 0.01℉/0.1℉. Probe input socket: Pt 100 ohm probe: DIN 4 pin socket. Thermocouple couple probe: Standard 2 pin type K socket.
|
|
ATE-2036 Thermometer
|
|
Operating Temperature: 0 to 50°C; Operating Humidity: Less than 85%R.H. Circuit: Custom one-chip of microprocessor LSI circuit. Display: LCD size: 2.1x1.5in/52x38mm, LCD with green backlight (ON/OFF). Channels: T1, T2, T3, T4, T1-T2. Sensor type: Type K thermocouple probe, Type J/T/E/R/S thermocouple probe, PT 100ohm probe. Cooperate with 0.00385 alpha coefficient, meet DIN IEC 751. Resolution: 0.1°C/1°C, 0.1°F/1°F. Interface: RS-232, USB via interface converter |
|
ATE-2036BT Thermometer, Real Time SD Memory Card Datalogger with Bluetooth interface
|
|
Operating Temperature: 0 to 50°C; Operating Humidity: Less than 85%R.H. Circuit: Custom one-chip of microprocessor LSI circuit. Display: LCD size: 2.1x1.5in/52x38mm, LCD with green backlight (ON/OFF). Channels: T1, T2, T3, T4, T1-T2. Sensor type: Type K thermocouple probe, Type J/T/E/R/S thermocouple probe, PT 100ohm probe. Cooperate with 0.00385 alpha coefficient, meet DIN IEC 751. Resolution: 0.1°C/1°C, 0.1°F/1°F, Interface: RS-232, USB via interface converter, Bluetooth |
|
ATE-2450 IR Calibrator
|
|
IR Calibrator. Temperature Range: 50°C to 500°C / 122°F to 932°F. Target size: 2.25in (57mm). Target Emissivity: 0.95. Resolution: 0.1°C/°F. Size: 180x114x233mm / 7.1x4.5x9.2in. Weight: 2.7kg / 6lb. |
|
ATE-2509 Infrared Thermometer
|
|
IR Measurement Range: -60 to 1000°C (-76 to 1832°F). IR Accuracy: ± 1°C (1.8°F): Object Temp. = 15 to 35°C, Ambient Temp. = 25°C; ± 2% of reading or ±2°C ( ±4°F) whichever is greater. Object Temp. = -33 to 1000°C. Ambient Temp. = 23±3°C. Type K Thermometer range: -64 to 1400°C (-83.2 to 1999°F). Type K Thermometer accuracy: ±1% of reading or ±1°C (±1.8°F), Test under T ambient = 23±5°C. Resolution: 0.1°C/0.1°F. <1,000°C/<1,000°F; 1°C/1°F. ≥1,000°C /≥1,000°F. Measurement Wavelength Region: 8 to 14μm. Sampling Time: Approx. 0.7 second. Operating Temperature: 32 to 122°F/0 to 50°C. Operating Humidity: Less than 80%RH. |
|
ATE-2520 Infrared Thermometer
|
|
Measurement range: -20 °C ÷ 500 °C. Resolution: 0,3 °C. Measured values: max, min, max-min, average, ambient temperature. Range selection: automatic. Field of view: 8÷1. Back light. Laser power < 1 mW. Battery indicator. Data hold. Auto power off
|
|
ATE-2523 Infrared Thermometer
|
|
Meas. ranges: -50.0°C to 760°C /-58.0°F to 1400°F; Sample rate: Less than 1 second; Basic accuracy: ±2% of reading or ±2°C/±4°F; Resolution: 0.1°C/1°C; Over range indication: LCD will show "OL" and "-OL"; Polarity: Automatic (no indication for positive polarity); Minus (-) sign for negative polarity; Emissivity: 0.95 fixed value; Field of view: D/S = 10:1; Diode laser: Output <1mW, Wavelength 630~670nm, class 2 (II) Laser product; Spectral response: 6~14μm; Power off: Automatic shut off after 7 seconds, approx.; Operating temp.: 0°C to 50°C (32°F to 122°F); Storage temp.: -20°C to 60°C (-4°F to 140°F)
|
|
|
|