Aktakom Power Manager Max
Aktakom Power Manager Max
Aktakom Power Manager Max software allows users to remotely control their power supply via PC. It features Measure, Set Up and Initialization functions, as well as, automatic switching off of the outputs of the device at the end of the program. The program follows basic configurations and some features of operation as the device control panel.
Software Specification
Supported communication interface
|
USB, LAN
|
Load voltage indication
|
Yes
|
Load current indication
|
Yes
|
Load power indication
|
No
|
Indication of operation under load
|
No
|
Operating mode indication
|
V C / C C
|
Digital input of voltage and current values
|
Yes
|
Regulator for entering voltage and current values
|
Horizontal - Sliding
|
Output on/off button
|
Yes
|
Preset fixed voltage values
|
Yes
|
Preset fixed current values
|
Yes
|
Voice guide
|
Yes (On / Off), Eng
|
Activate remote control mode
|
Any first command sent from a PC to a power supply using USB or LAN
|
Switch to manual control mode
|
"Res" command sent from a software or turn the power supply off and on
|
Displaying the history of load voltage and current values
|
No
|
Work according to a given schedule of current and voltage values
|
No
|
Saving and importing current and voltage schedules
|
No
|
Current time clock
|
On / Off
|
Button names
|
On / Off
|
Help
|
Yes
|
Language support
|
EN, ES
|
News
|
On / Off
|
Note: Any first command sent from a PC to a power supply using USB or LAN switches power supply to remote control mode. To switch power supply back to manual control mode please use a software to send "Res" command or turn the power supply off and on.
The software is multifunctional and interactive, its pre-set function allows for faster set up and flawless changes. Besides functionality the software has "News" button shows or hides Aktakom news feed. "Info" button displays the information about the program and connected device, and of cause the "Help" button for those who are stuck and need a little help. "Voice" button selects a Windows voice guide that will announce application events to you. Select the "No voice" option to disable the voice guide.
Standard package
The software in the standard package of the device has no physical media (CD) and can be downloaded at www.tmatlantic.com after the purchasing and registering the equipment with a serial number. This software is not free however its cost is included into device value.
Frequently Asked Questions
What languages does the voice guide support?
What are the advantages of APM Max Pro vs APM Max?
What languages does the voice guide support? |
Voice guidance works in all languages installed in the operating system on your PC.
Up
|
What are the advantages of APM Max Pro vs APM Max? |
APM Max Pro has additional functions comparing to APM Max:
- Automatic control of the power supply output voltage and current in accordance with the pre-set sequence of commands;
- Event log (in text format);
- Measurement history graph;
- Customizable user interface: you can hide and collapse all the blocks of the main window you don't need and leave only the ones you need. Also you can choose to hide or show the manual control blocks, control presets, synchronization, news feeds. User interface settings can be saved and restored.
Software Function
|
Max Pro
|
Max
|
Connection, communication
|
USB, LAN
|
USB, LAN
|
Load voltage indication
|
Yes
|
Yes
|
Load current indication
|
Yes
|
Yes
|
Load power indication
|
Yes
|
No
|
Indication of operation under load
|
Yes
|
No
|
Operating mode indication
|
VC/CC
|
VC/CC
|
Digital input of voltage and current values
|
Yes
|
Yes
|
Regulator for entering voltage and current values
|
Horizontal - Sliding
|
Horizontal - Sliding
|
Output on/off button
|
Yes
|
Yes
|
Preset fixed voltage values
|
Yes
|
Yes
|
Preset fixed current values
|
Yes
|
Yes
|
Voice guide
|
Yes (ON/OFF), Eng.
|
Yes (ON/OFF), Eng.
|
Activate remote control mode
|
Any first command sent from a PC to a power supply using USB or LAN
|
Any first command sent from a PC to a power supply using USB or LAN
|
Switch to manual control mode
|
"Res" command sent from a software or turn the power supply off and on
|
"Res" command sent from a software or turn the power supply off and on
|
Displaying the history of load voltage and current values
|
Yes
|
No
|
Work according to a given schedule of current and voltage values
|
Yes
|
No
|
Saving and importing current and voltage schedules
|
Yes
|
No
|
Current time clock
|
On/Off
|
On/Off
|
Button names
|
On/Off
|
On/Off
|
Help
|
Yes
|
Yes
|
Language support
|
EN ES
|
EN ES
|
News
|
On/Off
|
On/Off
|
Up
|
ALL RIGHTS RESERVED. AKTAKOM™ software is protected under International and Federal Copyright Laws and Treaties. Any unauthorized copy, reprint or use of this material is prohibited. No part of this software may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying, recording, or by any information storage and retrieval system without express written permission from the author / publisher. Windows, Windows logo are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or other countries. Back to the section
|